Its other advantages include a simple installation, where only a loop is made from the HDR. There are 2 cables going back to the HDR, where one of them is a backup circuit. In the event of a power failure, it is immediately supplied with energy from the inverter. Another possible connection is the connection of the entire house to backup, where in the event of a power failure it is necessary to manually switch and behave in such a way as not to overload the inverter in the house. (turn off boiler, electric boiler, hot water heater, electric underfloor heating, etc.) It is possible to easily install a backup socket circuit from this switchboard (screwless terminals for L1, L2, L3, N, PE protected by a current protector).
Dimensions - 543x750x140mm
Installation - On the wall
Material - Sheet steel
Protection - IP 41
Color - White, RAL 9016
Rated voltage - 230/400VAC, 50/60Hz
Rated current - max. 40A
Cable leads - upper + lower